首页 | 本学科首页   官方微博 | 高级检索  
     

DI型移动室带式真空过滤机气控系统故障分析及处理
引用本文:汪任初. DI型移动室带式真空过滤机气控系统故障分析及处理[J]. 有色设备, 2006, 0(6): 27-29
作者姓名:汪任初
作者单位:中国铝业中州分公司,特种氧化铝厂,河南,焦作,454174
摘    要:介绍D11250移动室带式真空过滤机气控系统的工作原理及其存在的问题,分析其产生的原因,提出相应的改造措施并实施,取得了良好的效果。

关 键 词:带式过滤机  二位五通换向阀  光电开关  切换阀
文章编号:1003-8884(2006)06-0027-03

Fault Analysis and Treatment of Air-Control System for DI Vacuum Belt Filter with Movable Cavity
WANG Ren-chu. Fault Analysis and Treatment of Air-Control System for DI Vacuum Belt Filter with Movable Cavity[J]. Non-ferrous Metallurgical Equipment, 2006, 0(6): 27-29
Authors:WANG Ren-chu
Affiliation:Special Alumina Factory, Zhongzhou Branch, CHALCO., Jiaozuo 454174, China
Abstract:The paper recommends the working principle of air-control system for DI1250 belt filter with movable vacuum cavity and the problems existed in working, analyzes the reason for the problem arising, puts forward and implements relevant rebuilding measures, which achieves good effects.
Keywords:belt filter   switch valve with two-position and five-pass   photoelectric switch   switch valve