首页 | 本学科首页   官方微博 | 高级检索  
     


Failure analysis of a high-temperature thermocouple
Authors:K. Gates  S. Benhaddad
Affiliation:(1) Thermex Metal Treating, 4734 18 St., T6P 1N8 Edmonton, AB, Canada;(2) Versa Power Systems, 4852 52 St. SE, T2B 3R2 Calgary, AB, Canada
Abstract:A solid oxide fuel cell unit operates at high temperatures of 700 to 800°C. The operation of the unit is controlled by a set of instrumentation including sensors, thermocouples, and voltage leads. Two S-thermocouples were inserted in the after-burner where temperature is constantly at 1000°C. During operation of one prototype unit and after 1000 h, the thermocouples started to give erratic readings and led to complete shutdown of the unit. Analysis of the thermocouples revealed a series of events may have occurred due to stress induced by the design, materials and operating conditions, contamination during manufacturing, or a reducing environment caused by sheathing. The specification from S-type to B-type may remove the risk of reoccurrence. A design change in platinum burner thermocouples to ensure an oxygen-rich environment for the platinum was also recommended.
Keywords:catastrophic failure  contamination  failure analysis  high temperature  materials selection  metallurgical investigation  nonferrous metals
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏