特高压线路外绝缘设计软件的污耐压算法
引用本文:周远翔,胡航海,黎小林,徐旭,黄莹,梁曦东,关志成.特高压线路外绝缘设计软件的污耐压算法[J].高电压技术,2007,33(11):23-26,32.
作者姓名:周远翔  胡航海  黎小林  徐旭  黄莹  梁曦东  关志成
作者单位:1. 清华大学电机系电力系统及发电设备控制和仿真国家重点实验室,北京,100084
2. 中国南方电网技术研究中心,广州,510623
基金项目:国家科技支撑计划重大项目
摘    要:随着输电架空线路的电压等级不断提高,外绝缘设计成为建设特高压工程的关键问题。为了开发出一套功能完善的特高压输电线路外绝缘设计软件,研究了外绝缘设计方法并转化成可行的软件算法。在绝缘子污耐压特性研究的基础上,重点研究了污耐压法作为一种算法在进行外绝缘设计时所需考虑的问题,主要是盐密、灰密、污秽不均匀以及海拔等多因素对绝缘子闪络电压的影响和修正问题,并探讨了污耐压法的计算步骤,确定了污耐压法作为一种算法进行外绝缘设计的规则以及具体的实现过程。

关 键 词:特高压  输电线路  外绝缘设计软件  算法  污耐压法  污闪
文章编号:1003-6520(2007)11-0023-04
收稿时间:2007-10-16
修稿时间:2007年10月16

Pollution Withstand Voltage Algorithm of External Insulation Design Software for UHV Overhead Line
ZHOU Yuan-xiang,HU Hang-hai,LI Xiao-lin,XU Xu,HUANG Ying,LIANG Xi-dong,GUAN Zhi-cheng.Pollution Withstand Voltage Algorithm of External Insulation Design Software for UHV Overhead Line[J].High Voltage Engineering,2007,33(11):23-26,32.
Authors:ZHOU Yuan-xiang  HU Hang-hai  LI Xiao-lin  XU Xu  HUANG Ying  LIANG Xi-dong  GUAN Zhi-cheng
Affiliation:1(1.State Key Lab of Control and Simulation of Power Systems and Generation Equipments,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.China South Power Grid Technology Research Center,Guangzhou 510623,China)
Abstract:In order to develop a full-featured external insulation design software for ultra-high voltage transmission lines,researching the external insulation design methods and turning to practical software algorithms are the key points for the software development.The specific creepage distance method and pollution withstand voltage method are three commonly used methods of external insulation design in China.Each of the methods has the advantages and its limitations.Taking pollution withstand voltage method as the software algorithm,this paper deeply researches the influence and correction on insulators' flashover voltage from variant factors which should be considered in the external insulation design.The relationships between the insulators' flashover voltage and the factors including salt deposit density,non soluble deposit density,chemical components of salt deposit,uniformity of the pollution deposit,high altitude,ice coating,profile of insulator and suspension mode,etc.are elaborated as well as the calculation process of the method is also studied.Based on these studies,the implementation processes of the software algorithm are put forward.In addition,the selection and dimension of composite insulators in ultra-high voltage overhead line which are the key processes in the algorithm are stressed.
Keywords:ultra-high voltage  transmission line  external insulation design software  algorithm  pollution withstand voltage method  pollution flashover