首页 | 本学科首页   官方微博 | 高级检索  
     


Establishment of the design requirements for a flow blockage detection system through a LES analysis of the temperature fluctuation in the upper plenum
Authors:Seung-Hwan Seong  Won-Dae JeonSeok-Ki Choi  Seong-O Kim
Affiliation:Korea Atomic Energy Research Institute, Instrumentation and Control Human Factors Division, 150 Duckjin-Dong, Yusong-Gu, Daejeon 305-353, Republic of Korea
Abstract:When an assembly in a core is partially blocked, the temperature in the upper plenum fluctuates at an early stage. Therefore, the temperature fluctuation in the upper plenum can provide the information about a local blockage of an assembly. For developing the detection algorithm for the partial blockage, we analyzed the temperature fluctuation in the upper plenum due to the partial blockage in an assembly. The LES turbulence model in the CFX code was used for analyzing the temperature fluctuation in the upper plenum because the LES is suitable for analyzing the time dependent turbulence variables. After analyzing the temperature fluctuations in the upper plenum, we established basic design requirements for the flow blockage detection system through a FFT analysis and some statistical analysis. We concluded that response time of a measuring device was less than 13 m s and that it should cover a high temperature range of 1000 K. In addition, the resolution of the thermocouple was less than 2 K and its location should be within 25 cm from the exit of each assembly.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏