首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of sericin/collagen membranes as prospective wound dressing biomaterial
Authors:Akturk Omer  Tezcaner Aysen  Bilgili Hasan  Deveci M Salih  Gecit M Rusen  Keskin Dilek
Affiliation:1Department of Engineering Sciences, Middle East Technical University, 06531 Ankara, Turkey;2Graduate Department of Biotechnology, Middle East Technical University, 06531 Ankara, Turkey;3Faculty of Veterinary Medicine, Department of Surgery, Ankara University, 06110 Ankara, Turkey;4Faculty of Medicine, Department of Pathology, Gulhane Military Medical Academy, Ankara, Turkey
Abstract:Sericin, a silk protein, has high potential for use in biomedical applications. In this study, wound dressing membranes of Sericin (S) and Collagen (C) were prepared by glutaraldehyde cross-linking at S/C; 2:1, 1:1, 1:2, and 0:1 weight ratios. They were stable in water for 4 weeks. However, increasing the proportion of sericin had decreasing effect on the membrane stability. Water swelling property of membranes was enhanced with sericin. The highest water swelling was obtained in 1:1 group (9.06 g/g), but increasing collagen or sericin content in the membranes had a diminishing effect. Highest water vapor transmission rate was obtained with 1:2 group (1013.80 g/m2/day). Oxygen permeability results showed that 1:2 (7.67 mg/L) and 2:1 (7.85 mg/L) S/C groups were better than the other groups. While sericin decreased the tensile strength and elongation of membranes, it increased modulus. Sericin also increased brittleness of membranes, but their UTS range (24.93–44.92 MPa) was still suitable for a wound dressing. Membranes were not penetrable to microorganisms. Cytotoxicity studies showed that fibroblasts and keratinocytes attached and gained their characteristic morphologies. They also proliferated on membranes significantly. After 1 week of subcutaneous implantation, a fibrous capsule formed around all membranes with an acute inflammation. Sericin containing membranes showed signs of degradation (at 2nd week), while collagen only membranes remained largely intact. Eventually, sericin containing membranes degraded in 3 weeks with moderate inflammatory response. Overall results suggest that sericin/collagen membranes would be favorable as wound dressing material when sericin ratio is less than or equal to the collagen component.
Keywords:Sericin   Collagen   Wound dressing   Membrane   Biocompatibility
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号