首页 | 本学科首页   官方微博 | 高级检索  
     

平流沉淀池运行中存在的问题及改造措施
引用本文:王旭宁,孙学东,姜红安,赵红志,李实.平流沉淀池运行中存在的问题及改造措施[J].中国给水排水,2006,22(10):27-30.
作者姓名:王旭宁  孙学东  姜红安  赵红志  李实
作者单位:保定中法供水有限公司,河北,保定,071000
摘    要:北方某水厂的平流沉淀池在运行中存在以下问题:冬季池表面结冰、吸泥机运转不正常;池底积泥不均匀,导致吸泥机排泥浓度变化大,影响污泥处理系统的正常运行;出水集水槽不在同一水平面,引起矾花上浮.针对这些问题,设计、安装了冬季融冰系统;对虹吸吸泥机的主体进行了改造,并根据原水水质采取变频运行;使用一种简单快捷的调整方法将出水集水槽调平,改善了沉后水水质.

关 键 词:平流沉淀池  冬季融冰  吸泥机改造  集水槽调平
文章编号:1000-4602(2006)10-0027-04
收稿时间:2006-02-08
修稿时间:2006-02-08

Problems Existing in the Operation of Horizontal Flow Sedimentation Tank and Their Improving Measures
WANG Xu-ning,SUN Xue-dong,JIANG Hong-an,ZHAO Hong-zhi,LI Shi.Problems Existing in the Operation of Horizontal Flow Sedimentation Tank and Their Improving Measures[J].China Water & Wastewater,2006,22(10):27-30.
Authors:WANG Xu-ning  SUN Xue-dong  JIANG Hong-an  ZHAO Hong-zhi  LI Shi
Affiliation:Baoding Sino-French Water Supply Company Limited, Baoding 071000, China
Abstract:Many problems existed in the operation of horizontal flow sedimentation tank in a northern water treatment plant. For example, the surface of the tank was frozen in winter and the siphon sludge collector was abnormal in operation. Uneven sludge depositing at the bottom of the tank resulted in high variation of sludge concentration and an abnormal operation of the sludge treatment system. Flocs float because the outlet collectors were not in the same level. In order to solve the problems, a device for ice thawing in winter was installed, the siphon sludge collector was modified and an operation of frequency conversion was employed according to raw water quality. The outlet collectors were adjusted to the same level using a simple method. Under the improvements, the outlet water quality of the sedimentation tank was improved.
Keywords:horizontal flow sedimentation tank  ice thawing in winter  modification of siphon sludge collector  horizontal adjustment of the outlet collectors