摘    要:结合西北电网高一级电压等级可行性研究,按西北电网负荷分布、负荷特性以及对西北地区动力资源的分析,提出西北电网出现高一级电压等级的必要性及可行性。重点介绍500k V及750k V 两个电压等级方案。从西北电网本身情况出发,推荐采用750k V 电压等级方案。

关 键 词:西北电网  电压等级  可行性研究  负荷分布  负荷特性  动力资源  750kV电压等级  500kV电压等级

Higher Voltage Level Selection of Northwest Power System
Yang Panfeng. Higher Voltage Level Selection of Northwest Power System[J]. Northwest China Electric Power, 1999, 27(4): 13-20
Authors:Yang Panfeng
Abstract:The necessity and feasibility of higher voltage level appearance in northwest poer system is put forward,by combining the feasibility study of higher voltage level innorthwest power system,and according to the loas distribution of the system,load characteristic and power resources analysis in northwest China.The 500kV and 750kV voltage level schemes are discussed in detail.From the point of the actual conditions in northwest power system,the 750kV voltage scheme is recommended as the higher voltage level of system.
Keywords:northwest power system higher voltage level feasibility study load distribution load character 750kV voltage level 500kV voltage level