首页 | 本学科首页   官方微博 | 高级检索  
     


Synchrotron radiation X‐ray micro‐fluorescence: Protocol to study mesenchymal stem cells
Authors:Karla Mayra Rezende  Marcelo Bönecker  Carlos Alberto Perez  Andrea Mantesso
Affiliation:1. Department of Pediatric Dentistry, University of S?o Paulo, S?o Paulo, Brazil;2. XRF Line, Brazilian Synchrotron Light Laboratory, Campinas, Brazil;3. Department of Oral Pathology, University of S?o Paulo, S?o Paulo, Brazil
Abstract:The micro‐X‐ray fluorescence by synchrotron radiation (μ‐XRF) is a method to determine the composition of tissues without destroying the samples. However, this technique has never been used for the analysis of mesenchymal stem cells (MSC). This study compared different protocols for fixing, storing, preserving, and establishing the correct numbers of dental derived MSC submitted to μ‐XRF analysis. Stem cells were obtained from human dental tissue. After cell expansion, and MACS isolation, the samples were fixed and the following quantities of cells 1 × 104 to 1 × 107 were divided in two groups: G1: fixed in 4% paraformaldehyde diluted in phosphate‐buffered saline solution, and G2: fixed in 4% paraformaldehyde diluted in MilliQ water. The G1 cells showed precipitation of chemical components from the solution resulting in the formation of salt crystals while G2 cells were clear and almost transparent in the sample holder. With regards to cells concentration, the best results occurred when four droplets of 1 × 107 cells were analyzed. This work shows that to identify and study the distribution of trace elements in MSC by μ‐XRF, the best protocol is fixation in 4% paraformaldehyde diluted with MilliQ water at 4°C and a concentration of four incremental droplets of 1 × 107 cells. Microsc. Res. Tech. 79:149–154, 2016. © 2016 Wiley Periodicals, Inc.
Keywords:X‐ray analysis  trace elements  stem cells  protocols  synchrotron radiation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号