首页 | 本学科首页   官方微博 | 高级检索  
     

双级轴流式一次风机叶片飘移原因分析
引用本文:钱红祥.双级轴流式一次风机叶片飘移原因分析[J].水利电力机械,2010(2):44-45,50.
作者姓名:钱红祥
作者单位:广东珠三角电力工程技术有限公司;
摘    要:分析了轴流式风机在实际生产中发生失速和喘振的原因,论述了600MW机组双级轴流式一次风机运行中叶片飘移的原因,提出了在检修工作中应注意的问题,给出了针对性的解决措施。

关 键 词:轴流式风机  叶片飘移  失速  喘振

Cause analysis of double-stages axial-flow primary fan blades drifting
QIAN Hong-xiang.Cause analysis of double-stages axial-flow primary fan blades drifting[J].Water Conservancy & Electric Power Machinery,2010(2):44-45,50.
Authors:QIAN Hong-xiang
Affiliation:QIAN Hong-xiang(Guangdong Pearl Delta Electric Power Engineering Technology Corporation Limited,Taishan 529228,China)
Abstract:The causes of stall and surge of axial-flow fan during practical operating were analyzed,and the reasons of blade drifting of double stages axial-flow primary fan of 600MW unit in operation were discussed.The problems needing attention in overhaul were pointed out,and relevant solving measures were given.
Keywords:axial flow fan  blade drift  stall  surge  