摘    要:介绍了将FH1935低本底液体闪烁仪的原20mL样品瓶改造100mL样品瓶的过程,解决了一些具体问题。

关 键 词:最低探测限  FH1935低本底液体闪烁仪  技术改造

The reform of low-background liquid scintillation spectrometer
WANG Sha lingZhejiang Province Environmental Radiation Monitoring Center,Hangzhou.The reform of low-background liquid scintillation spectrometer[J].Nuclear Electronics & Detection Technology,2000,20(6):480-482.
Authors:WANG Sha lingZhejiang Province Environmental Radiation Monitoring Center  Hangzhou
Affiliation:WANG Sha lingZhejiang Province Environmental Radiation Monitoring Center,Hangzhou 310012
Abstract:This article introduces the whole procedure about FH1955 Low Background Liquid Scintillation Spectrometer from 20 mL sample bottle transformed into 100 mL, and its solaed special problems. The reform result is that the lowest limit of detection changed from 1.72 Bq/L to 1.23 Bq/L, and introduced the result about mading the item.