首页 | 本学科首页   官方微博 | 高级检索  
     

FH1935低本底液体闪烁仪的改造
引用本文:王沙陵. FH1935低本底液体闪烁仪的改造[J]. 核电子学与探测技术, 2000, 20(6): 480-482
作者姓名:王沙陵
作者单位:浙江省环境放射性监测站,杭州
摘    要:介绍了将FH1935低本底液体闪烁仪的原20mL样品瓶改造100mL样品瓶的过程,解决了一些具体问题。

关 键 词:最低探测限 FH1935低本底液体闪烁仪 技术改造

The reform of low-background liquid scintillation spectrometer
WANG Sha lingZhejiang Province Environmental Radiation Monitoring Center,Hangzhou. The reform of low-background liquid scintillation spectrometer[J]. Nuclear Electronics & Detection Technology, 2000, 20(6): 480-482
Authors:WANG Sha lingZhejiang Province Environmental Radiation Monitoring Center  Hangzhou
Affiliation:WANG Sha lingZhejiang Province Environmental Radiation Monitoring Center,Hangzhou 310012
Abstract:This article introduces the whole procedure about FH1955 Low Background Liquid Scintillation Spectrometer from 20 mL sample bottle transformed into 100 mL, and its solaed special problems. The reform result is that the lowest limit of detection changed from 1.72 Bq/L to 1.23 Bq/L, and introduced the result about mading the item.
Keywords:low background  liquid scintillation spectrometer  transform  lowest limit of detection  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号