摘    要:对Fenton试剂处理焦化废水进行了研究,通过探讨H2O2投加量、Fe^2+]/H2O2]、pH值、反应温度等因素对COD去除率的影响,确定了以下操作条件:H2O2投加量158mmol/L,nFe^2+]/nH2O2]=1:10,pH=3,反应温度为30℃。在上述条件下,焦化废水COD去除率达89.9%。在此基础上,研究了H2O2投加方式对处理效果的影响。结果表明,H2O2采用分批投加时,会改善处理效果。

关 键 词:Fenton试剂  焦化废水  COD去除率
文章编号:1004-0935(2006)03-0147-03
收稿时间:2005-10-20
修稿时间:2005-10-20

Study on the Treatment of Coking Wastewater by Fenton Reagent
WANG Chun-min,BU Qi-jun,WANG Wei-jun.Study on the Treatment of Coking Wastewater by Fenton Reagent[J].Liaoning Chemical Industry,2006,35(3):147-149,183.
Authors:WANG Chun-min  BU Qi-jun  WANG Wei-jun
Abstract:The pollution situation of the virulent organic pollutant in the key water source area of Fuxin has been investigated and analyzed in this paper. The results showed this water source was mainly polluted by the Volatile Organic Compounds- Carbon etraohloride, Toluene, TRichloroethene, Thtrachloroethene 1,4 - Dichloro - benzene, 1,2,4 - Trichloro - benzene. Some control were put forward.
Keywords:Key water source area  Organic pollutant  Pollution  Prevention