CO装置汽提气冷凝器腐蚀原因分析
引用本文:金丁.CO装置汽提气冷凝器腐蚀原因分析[J].化学工业与工程技术,1999,20(1):37-39.
作者姓名:金丁
作者单位:上海太平洋化工(集团)公司焦化总厂
摘    要:介绍了不锈钢换热器的腐蚀情况。通过直观检查腐蚀现象,对比晶间腐蚀、应力腐蚀及晶间应力腐蚀,确定为晶间应力腐蚀,并分析了腐蚀产生的原因。根据晶间应力腐蚀产生机理,在制造上采取了一系列措施后,腐蚀现象得以消除或缓解

关 键 词:不锈钢  晶间腐蚀  应力腐蚀  晶间应力腐蚀

Corrosion cause analysis of stripping gas condenser in CO unit
Jin Ding.Corrosion cause analysis of stripping gas condenser in CO unit[J].Journal of Chemical Industry & Engineering,1999,20(1):37-39.
Authors:Jin Ding
Abstract:The corrosion status of the heat exchanger of the stainless steel was described. Through directly inspecting of corrosion phenomenom, comparing the intergranular corrosion, stress corrosion and intergranular-stress corrosion, the intergranular-stress corrosion was determined as major corrosion type and the corrosion cause was analyzed. According to the mechanism of the formation of interganular-stress corrosion, a series of measures were adopted for equipment manufacture, so the corrosion phenomenom was eliminated or mitigated.
Keywords:Stainless steel  Intergranular corrosion  Stress corrosion  Intergranular-stress corrosion  