首页 | 本学科首页   官方微博 | 高级检索  
     


A DRYING HEAT PUMP USING CARBON DIOXIDE AS WORKING FLUID
Authors:K Kl  cker  E L Schmidt  F Steimle
Affiliation:  a Institute of Applied Thermodynamics and Air Conditioning (IATK), University of Essen, Essen, Germany
Abstract:The application of carbon dioxide as working fluid in refrigeration and heat pump systems is regaining increasingly importance in view of the chlorofluorocarbon (CFC) substitution problem. It is both under ecological and economical aspects an attractive alternative to the hydrofluorocarbon (HFC) working fluids being in practical use. The thermophysical properties and characteristics of carbon dioxide are quite different from those of refrigerants used in conventional vapour compression cycles. Its application in conventional vapour compression refrigerating systems is limited by its critical parameters (tc = 31.1°C and pc = 73.8 bar). The possibility to use carbon dioxide also beyond these limits in high temperature processes, e.g., heat pumps, is given by the application of a trans-critical process. The design and construction of a commercial drying heat pump system (batch type cabinet dryer with 12 kW heating capacity and closed air circuit) using the natural working fluid carbon dioxide is shown and experimental results of investigations carried out are presented. Possible energy savings calculated theoretically are given for comparison.
Keywords:Batch drying  Energy savings  Laundry drying
本文献已被 InformaWorld 等数据库收录!