首页 | 本学科首页   官方微博 | 高级检索  
     

三河发电厂~#4发电机氢气露点温度超标原因分析
引用本文:王占彬,李毅刚,周强. 三河发电厂~#4发电机氢气露点温度超标原因分析[J]. 西北煤炭, 2010, 8(2)
作者姓名:王占彬  李毅刚  周强
作者单位:神华国华三河发电有限责任公司,河北,三河,065201 
摘    要:通过对三河电厂2009年4月24日-5月8日#4发电机氢气露点温度超标原因的分析,及时发现了除湿装置的操作问题,并及时给予改正,从而保证了机组的安全稳定运行.

关 键 词:氢气  除湿装置  露点温度

The Analysis of the Reason of the Dew Point Temperature of Sanhe Power Plant ~#4.
Li Yigang,Wang Zhanbin,Zhou Qiang. The Analysis of the Reason of the Dew Point Temperature of Sanhe Power Plant ~#4.[J]. Northwest Coal, 2010, 8(2)
Authors:Li Yigang  Wang Zhanbin  Zhou Qiang
Affiliation:Li Yigang,Wang Zhanbin,Zhou Qiang (Sanhe Power Generation Co. Ltd.,Sanhe,Hebei,065201,China)
Abstract:This paper defines the analysis of the reason on excessive dew- point temperature of Hydrogen Generator # 4 of Sanhe Power Plant happened on April 24, 2009-May 8. In a timely manner, the dehumidification problem of the equipment was solved, thereby ensuring the unit safe and stable operation.
Keywords:hydrogen  dewpoint temperature  dehumidification equipment  