首页 | 本学科首页   官方微博 | 高级检索  
     

1000MW超超临界塔式锅炉燃烧优化调整
引用本文:潘国清,徐小琼,应明良,蔡洁聪.1000MW超超临界塔式锅炉燃烧优化调整[J].浙江电力,2011,30(7):30-33.
作者姓名:潘国清  徐小琼  应明良  蔡洁聪
作者单位:浙江省电力试验研究院,杭州,310014
摘    要:通过燃烧优化调整试验,有效地解决了1 000 MW超超临界塔式锅炉长期以来的结焦问题,同时也大大提高了再热汽温,降低了送、引风机的耗电量,增加了送、引风机的裕量,减少了NOX排放浓度,提高了锅炉整体安全性和经济性。

关 键 词:1000MW  超超临界  塔式锅炉  燃烧  优化  调整

Combustion Optimization for 1000MW Ultra-supercritical Tower Boiler
PAN Guo-qing,XU Xiao-qiong,YING Ming-liang,CAI Jie-cong.Combustion Optimization for 1000MW Ultra-supercritical Tower Boiler[J].Zhejiang Electric Power,2011,30(7):30-33.
Authors:PAN Guo-qing  XU Xiao-qiong  YING Ming-liang  CAI Jie-cong
Affiliation:PAN Guo-qing,XU Xiao-qiong,YING Ming-liang,CAI Jie-cong(Zhejiang Electric Power Test and Research Institute,Hangzhou 310014,China)
Abstract:The coking problem of 1 000 MW ultra-supercritical tower boilers which exists for a long time is solved effectively by combustion optimization tests.Meanwhile,the reheating steam temperature is significantly increased.The power consumption of forced and induced draft fans and the NOX emission concentration are reduced and the margins of these draft fans are greatly increased.Therefore the overall safety and economy of boilers are improved.
Keywords:1 000 MW  ultra-supercritical  tower boiler  combustion  optimization  adjustment  