首页 | 本学科首页   官方微博 | 高级检索  
     


Installation effects on vortex shedding flowmeters
Authors:M Takamoto  H Utsumi  N Watanabe  Y Terao
Affiliation:

National Research Laboratory of Metrology, Umezono 1-1-4, Tsukuba, Ibaraki, Japan 305

Abstract:Numerous measurements of the effects of pipe fittngs on vortex shedding flowmeters are carried out as a contribution to flow metering standards. A water test line of 150 mm diameter is used in the experiments covering a Reynolds number range of about 2 × 105 to 106. The effects of six kinds of piping configurations are examined at various upstream straight pipe lengths and all four kinds of liquid vortex shedding flowmeters, which were commercially available in Japan, are tested. The vortex shedding flowmeters are compared with a turbine meter in experiments designed to evaluate reproducibility of measurements. The uncertainty of the measured data is estimated at about 0.1%. It is found that the magnitude of each installation effect strongly depends on the design of the flowmeter. The experimental results are presented in detail and a table is given of the minimum upstream straight pipe lengths needed to suppress the effects to less than 0.5% for each of the tested flowmeters. This can be used as guidance in the installation of vortex shedding flowmeters.
Keywords:vortex flowmeters  installation effects  standards
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏