首页 | 本学科首页   官方微博 | 高级检索  
     

硫酸铁铵滴定法测定赤泥中二氧化钛
引用本文:朱晓波,李望,管学茂.硫酸铁铵滴定法测定赤泥中二氧化钛[J].冶金分析,2015,35(8):18-21.
作者姓名:朱晓波  李望  管学茂
作者单位:1. 河南理工大学材料科学与工程学院,河南焦作 454000; 2. 河南省高等学校矿业工程材料重点学科开放实验室,河南焦作 454000
基金项目:河南省高等学校重点科研项目(15A440014);河南理工大学博士基金(B2014-012)
摘    要:利用氢氧化钠的强碱性和消融性,将赤泥试样经氢氧化钠在马弗炉中加热熔融。熔融物先在温水中洗出,加入30 mL盐酸溶解,然后加入铝片还原,采用碳酸氢钠溶液保护,最后以硫氰酸铵溶液作为指示剂,采用硫酸铁铵滴定法测定赤泥中的二氧化钛含量。研究了样品用量、粒度、氢氧化钠用量、焙烧条件、溶样条件和保护溶液对测定的影响,结果表明:最佳实验条件是氢氧化钠用量为6 g、焙烧温度为650 ℃、焙烧时间为20 min、还原剂为2.2 g铝片、保护溶液为饱和碳酸氢钠溶液、滴定前放置时间不超过15 min。采用实验方法对实际赤泥样品中二氧化钛进行测定,测定值与电感耦合等离子体原子发射光谱法测得结果相近,相对标准偏差(n=5)均小于0.2%。

关 键 词:硫酸铁铵    二氧化钛    赤泥    保护溶液    滴定法  
收稿时间:2014-10-16

Determination of titanium dioxide in red mud by ammonium ferric sulfate titrimetry
ZHU Xiao-bo,LI Wang,GUAN Xue-mao.Determination of titanium dioxide in red mud by ammonium ferric sulfate titrimetry[J].Metallurgical Analysis,2015,35(8):18-21.
Authors:ZHU Xiao-bo  LI Wang  GUAN Xue-mao
Affiliation:1. School of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo 454000, China;2. Henan Key Discipline Open Laboratory of Mining Engineering Materials, Jiaozuo 454000, China
Abstract:The red mud sample was heated and fused in muffle furnace with sodium hydroxide using its strong basicity and ablation property. The fusant was firstly leached in worm water followed by dissolution with 30 mL of hydrochloric acid. Then, the aluminum sheet was added for reduction in presence of sodium bicarbonate solution for protection. Finally, the content of titanium dioxide in red mud was determined by ammonium ferric sulfate titrimetry using ammonium thiocyanate solution as indicator. The effect of sample dosage, particle size, sodium hydroxide dosage, roasting condition, sample dissolution condition and protection solution on the determination was investigated. The results showed that the optimal experimental conditions were as follows: the dosage of sodium hydroxide dosage was 6 g, the roasting temperature was 650 ℃, the roasting time was 20 min, the reducing agent was 2.2 g of aluminum sheet, the protection solution was saturated sodium bicarbonate solution, and the placing time before titration was less than 15 min. The proposed method was applied to the determination of titanium dioxide in actual red mud sample, and the found results were consistent with those obtained by inductively coupled plasma atomic emission spectrometry. The relative standard deviation (RSD, n=5) was less than 0.2%.
Keywords:ammonium ferric sulfate  titanium dioxide  red mud  protection solution  titrimetry  
本文献已被 CNKI 等数据库收录!
点击此处可从《冶金分析》浏览原始摘要信息
点击此处可从《冶金分析》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号