Non-contact laser-scanning confocal microscopy of the human cornea in vivo |
| |
Affiliation: | 1. Dartmouth College, United States;2. Stanford University School of Medicine, United States;3. Stanford University School of Medicine, 875 Blake Wilbur Drive, Stanford, CA 94305-5826, United States;1. Department of Bioimaging and Radiological Sciences, Catholic University School of Medicine, L.go A. Gemelli 8, 000168 Rome, Italy;2. Institute of Neurosurgery, Catholic University School of Medicine, L.go A. Gemelli 8, 000168 Rome, Italy;1. School of Mechanical Engineering, Xi’an Jiaotong University, 710049 Xi’an, PR China;2. The State Key Laboratory for Manufacturing Systems Engineering, 710049 Xi’an, PR China;3. Institute of Fluid Flow Machinery, Polish Academy of Science, 80-231 Gdansk, Poland;4. Faculty of Automotive and Construction Machinery, Warsaw University of Technology, 02-524 Warsaw, Poland;1. Department of Ophthalmology, Erasmus Medical Center, Rotterdam, The Netherlands;2. Department of Epidemiology, Erasmus Medical Center, Rotterdam, The Netherlands;3. Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands;4. Department of Ophthalmology, HagaZiekenhuis (Haga Hospital), The Hague, The Netherlands;1. Refractive Errors Research Center, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran;2. Department of Ophthalmology, Mashhad Medical University, Mashhad, Iran |
| |
Abstract: | PurposeTo investigate the utility of using non-contact laser-scanning confocal microscopy (NC-LSCM), compared with the more conventional contact laser-scanning confocal microscopy (C-LSCM), for examining corneal substructures in vivo.MethodsAn attempt was made to capture representative images from the tear film and all layers of the cornea of a healthy, 35 year old female, using both NC-LSCM and C-LSCM, on separate days.ResultsUsing NC-LSCM, good quality images were obtained of the tear film, stroma, and a section of endothelium, but the corneal depth of the images of these various substructures could not be ascertained. Using C-LSCM, good quality, full-field images were obtained of the epithelium, subbasal nerve plexus, stroma, and endothelium, and the corneal depth of each of the captured images could be ascertained.ConclusionsNC-LSCM may find general use for clinical examination of the tear film, stroma and endothelium, with the caveat that the depth of stromal images cannot be determined when using this technique. This technique also facilitates image capture of oblique sections of multiple corneal layers. The inability to clearly and consistently image thin corneal substructures – such as the tear film, subbasal nerve plexus and endothelium – is a key limitation of NC-LSCM. |
| |
Keywords: | Cornea Non-contact laser scanning confocal microscopy Tear film |
本文献已被 ScienceDirect 等数据库收录! |
|