Optical quality and intraocular scattering assessed with a double-pass system in eyes with contact lens induced corneal swelling |
| |
Affiliation: | 1. IOBA-Eye Institute, University of Valladolid, Valladolid, Spain;2. Center for Sensors, Instruments and Systems Development (CD6), Technical University of Catalonia, Terrassa, Barcelona, Spain;3. Department of Physics and Optics, School of Optometry, University of Valladolid, Valladolid, Spain;1. Department of Ophthalmology and Vision Science, The University of Arizona, Tucson, Arizona;2. College of Public Health, The University of Arizona, Tucson, Arizona;3. Optical Sciences Center, The University of Arizona, Tucson, Arizona;1. Ningbo No.2 Hospital, Ningbo, Zhejiang, 315010, China;2. Department of Anesthesiology, Yinzhou People''s Hospital, Medical School of Ningbo University, Ningbo, Zhejiang, 315040, China;3. Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang, 310027, China;4. Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals of Zhejiang Province, Ningbo Municipal Center for Disease Control and Prevention, Ningbo, Zhejiang, 315010, China;1. Institute for Materials Science, Biocompatible Nanomaterials, Christian-Albrechts-Universität zu Kiel, Kaiserstr. 2, D-24143 Kiel, Germany;2. Wöhlk-Contact-Linsen GmbH, Bürgermeister-Schade-Straße 16, D-24232 Schönkirchen, Germany;3. Zoological Institute, Zoophysiology, Christian-Albrechts-Universität zu Kiel, Olshausenstr. 40, D-24098 Kiel, Germany |
| |
Abstract: | PurposeTo evaluate the impact of contact lens (CL)-induced corneal swelling on the optical quality of the eye by means of the double-pass technique.MethodsMeasurements of 6 healthy subjects were obtained in 5 visits over 1 week, at baseline and after sleeping with 4 different CLs of +0.50 D, +2.00 D, +5.00 D and +8.00 D (Acuvue2), randomly fitted on 4 different days. The control eye wore no CL. Corneal pachymetry and optical quality of the eye (OQAS, Visiometrics) were measured once at baseline and at three interval times in the follow-up visits: immediately after CL removal, and 1 and 2 h after CL removal. Optical quality was evaluated by means of the Strehl ratio and OQAS values at 100%, 20% and 9% contrasts. Intraocular scattering was evaluated with the objective scatter index (OSI).ResultsMean overnight swelling was 5.98 ± 4.29% in CL-eyes versus 0.30 ± 0.78% in control eyes (p < 0.01). Corneal swelling was maximal immediately after CL removal and decreased with time (p < 0.01). A significant worsening in all optical quality parameters and a significant increase of the OSI were found in eyes with corneal swelling (p < 0.05). Two hours after CL removal there were no statistically significant differences (p > 0.05) between CL-eyes and control eyes in any of the measured parameters.ConclusionsCorneal swelling has a significant impact on the optical quality of the eye and on intraocular scattering as assessed with the double-pass technique. |
| |
Keywords: | Contact lens Overnight Contact swelling Optical quality Scattering |
本文献已被 ScienceDirect 等数据库收录! |
|