Affiliation:1. Fatih University Medical Faculty Hospital, Department of Ophthalmology, Istanbul, Turkey;2. Turkiye Hospital Eye Clinic, Istanbul, Turkey;3. Department of Ophthalmology, Gaziantep University School of Medicine, Gaziantep, Turkey;1. Gaziosmanpaşa Taksim Training and Research Hospital, Department of Ophthalmology, Istanbul, Turkey;2. Beyoglu Eye Training and Research Hospital, Istanbul, Turkey;3. Istanbul Medeniyet University, Department of Ophthalmology, Istanbul, Turkey;1. Centro Medico Teknon, Barcelona, Spain;2. Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal;3. Universidad Politécnica de Cataluña, Terrasa, Spain;1. Ophthalmic Research Group, Aston University, Birmingham, UK;2. Johnson & Johnson Vision Care, Wokingham, Berkshire, UK
Abstract:PurposeTo compare intraocular pressure (IOP) measured with ocular response analyzer (ORA) with and without soft contact lenses (CL) on eye.MethodsGoldmann correlated intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) were measured in 56 eyes of 28 subjects without any ocular pathology, using ORA. One eye was fitted with Narafilcon A (1-Day Acuvue True Eye, Johnson & Johnson) and the other eye with Nelfilcon A (Daily AquaComfort Plus, Ciba Vision), each with −3.00D and IOPg and IOPcc were again measured over CL. The variation in the IOP with and without CL was determined.ResultsOut of 28 subjects, 54% (15) were female. Mean age of the subjects was 29.4 ± 9.8 years. Both the IOPg and IOPcc when measured with CL, were found statistically significantly lower than without CL (p < 0.05). In subjects wearing Narafilcon A lens, IOPg and IOPcc were found 0.88 ± 2.04 mmHg and 1.55 ± 2.16 mmHg lower than without CL, respectively. Similarly, with Nelfilcon A lens, IOPg and IOPcc were found to be 1.03 ± 1.93 mmHg and 1.62 ± 3.12 mmHg lower, respectively. IOPcc was highly affected and underestimated by more than 3 mmHg in upto 36% of the subjects.ConclusionMeasurement of IOP over minus (−3.00D) CL with ORA is dependent upon CL properties when measured in normal IOP population. It showed lower IOP over Narafilcon A and Nelfilcon A soft CL in comparison to the pressures measured without lenses. IOPg was found less affected by CL. For the accurate measurement of IOP with ORA, CL should be removed.
Keywords:Ocular response analyzer  Corneal compensated intraocular pressure  Goldmann correlated intraocular pressure  Soft contact lens
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号