首页 | 本学科首页   官方微博 | 高级检索  
     

105电火帽的真实静电感度测试
引用本文:魏光辉,刘尚合. 105电火帽的真实静电感度测试[J]. 火工品, 1999, 0(3): 22-24
作者姓名:魏光辉  刘尚合
作者单位:军械工程学院静电技术研究所,河北,石家庄,050003
摘    要:简要介绍了电火工品真实静电感度的测试方法,以导电药式电火工品静电临界点火能量服从对数正态分布为基础,给出了对应的数据处理方法。测试了105电火帽的真实静电感度,确定了其静电最小点火能量的置信区间。

关 键 词:电火工品  静电感度  数据处理方法  测试  电火帽
文章编号:1003-1480(1999)03-0022-03
修稿时间:0199-05-19

Real Electrostatic Sensitivity Tests for 105 Electric Primers
WEI Guang-hui,LIU Shang-he. Real Electrostatic Sensitivity Tests for 105 Electric Primers[J]. Initiators & Pyrotechnics, 1999, 0(3): 22-24
Authors:WEI Guang-hui  LIU Shang-he
Abstract:This paper briefly introduces the method of testing the real sensitivity for EED and gives the data processing method in terms of the electrostatic critical ignition energy of conductive powder EED conforming to logarithmic normal distribution. In light of the above, the real electrostatic sensitivities of 105 electric primers are tested and the confidence interval of its minimum electrostatic ignition energy is determined.
Keywords:EED  Electrostatic sensitivity  Data processing method  Test  Electric primer