Behavior of eccentrically loaded concrete-filled GFRP tubular short columns |
| |
Authors: | WANG Qing-xiang GUAN Hong-bo RUAN Bing-feng |
| |
Affiliation: | State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian 116024, China |
| |
Abstract: | The glass fiber reinforced polymer (GFRP) tube is an effective material that can increase the bearing capacity and ductility of concrete.To study the mechanical behavior of this composite structure,twenty-one concrete-filled GFRP tubular short columns were tested under an eccentric load.The principle influencing factors,such as the eccentricity ratio,concrete strength and ratio of longitudinal reinforcement were also studied.In addition,the course of deformation,failure mode,and failure mechanism were analyzed by observing the phenomena and summarizing the data.The test results indicated that the strength and deformation characteristics of core concrete increase as a result of the addition of the GFRP tube.However,the gain in strength due to the addition of the GFRP tube decreases as the ratio of e /d increases.An increase in the longitudinal steel ratio can improve the bearing capacity of the composite short column effectively.Furthermore,the study showed that the constraint effect of the GFRP tube on high-strength concrete is not as effective as that on common concrete.The reason is that the lateral deformation of the high-strength concrete is less than that of the common concrete when the concrete column was tested under the same axial compression ratio. |
| |
Keywords: | GFRP tube eccentric loading concrete short column composite structure |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
| 点击此处可从《哈尔滨工业大学学报(英文版)》浏览原始摘要信息 |
|
点击此处可从《哈尔滨工业大学学报(英文版)》下载全文 |