摘    要:重碳酸盐的分解是造成循环冷却水系统结垢的主要原因.从重碳酸盐的分解深度入手,推导了循环水系统中结垢量的理论公式,以期能为水质控制和化学清洗提供一个可资借鉴的依据.

关 键 词:结垢  重碳酸盐  循环冷却水系统  分解深度
修稿时间:1999-08-10

The calculation of quantitative scaling of recirculating cooling water system
Bai Xinping,Wang Zhifeng,Jin Jianping. The calculation of quantitative scaling of recirculating cooling water system[J]. Cleaning World, 2000, 16(2): 22-24
Authors:Bai Xinping  Wang Zhifeng  Jin Jianping
Abstract:The main reason of scaling of recirculating cooling water systems is decomposise of calcium bi-carbonate.The theoretical formal of the quantitative scaling of recirculating cooling water systems was given from the aspects of decomposition of bi-combonate. It will be applied for water controling and chemical cleaning.
Keywords:scaling bi-combonate recirculating cooling water system decomposise