分子筛故障分析及处理措施
引用本文:寇国,刘兴茂,袁镜清,刘继勇,岳阳. 分子筛故障分析及处理措施[J]. 广东化工, 2010, 37(2): 147-148
作者姓名:寇国  刘兴茂  袁镜清  刘继勇  岳阳
作者单位:塔里木油田开发事业部,新疆,库尔勒,841000
摘    要:通过对轮南气举气处理装置分子筛干燥系统存在的问题进行深入剖析,提出处理措施,以达到延长分子筛的使用寿命,提供露点合格的气举气。

关 键 词:天然气  分子筛  干燥塔  露点  吸附  粉化  变黑

Molecule Sieve Failure Analysis and Disposal Method
Kou Guo,Liu Xingmao,Yuan Jingqing,Liu Jiyong,Yue Yang. Molecule Sieve Failure Analysis and Disposal Method[J]. Guangdong Chemical Industry, 2010, 37(2): 147-148
Authors:Kou Guo  Liu Xingmao  Yuan Jingqing  Liu Jiyong  Yue Yang
Affiliation:Oil & Gas Exploitation Department of Tarim Oilfield;Korla 841000;China
Abstract:Throgh in-depth analysis of molecular sieve drying system problems of Lunnan gas-lifting disposal plant,disposal measures was Proposed to achieve extension of the life of molecular sieve and met the gas-lifting gas dewpoint qualified.
Keywords:natural gas  molecular sieve  drying tower  dewpoint  adsorption  pulverization  nigrescence  