首页 | 本学科首页   官方微博 | 高级检索  
     


Verzinkte Bauteile im Kontakt mit Spanngliedern
Authors:Andreas Burkert  Jens Lehmann  Annette Burkert  Jürgen Mietz  Gerd Eich
Abstract:Galvanized Elements in Contact with Prestressing Steel In order to clarify under which practical conditions real risks for hydrogen‐induced stress corrosion cracking of prestressing steels in contact with galvanized elements exist laboratory investigations in aqueous solutions and concrete as well as tests with stressed prestressing steels were carried out. While different distances between steel and zinc (cathode and anode) showed only a negligible influence on the polarisation of the steel a significant dependence on the area ratio steel/zinc was observed. A critical area ratio of 10:1 can be defined above which polarisation of the steel to hydrogen evolution potentials is unlikely. The results obtained in the laboratory concerning the critical area ratio were confirmed by on‐site investigations in a precasting plant. Exposure tests with hydrogen loading did not lead to fractures during the testing time for approved prestressing steels. The characteristic mechanical values determined immediately after the hydrogen loading tests did not show significant changes. Thus, an indirect contact between prestressing steels and galvanized elements can be estimated as uncritical. But a direct contact has to be excluded by compliance with DIN 1045‐1, i.e minimal distance of 2 cm between prestressing steel and galvanized elements.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏