Electrochemical study of the corrosion behavior of Ce sealing of anodized 2024 aluminum alloy |
| |
Authors: | Xingwen Yu Chunan Cao |
| |
Affiliation: | a Department of Interface Chemistry and Surface Engineering, Max Plank Institute for Iron Research, D-40237 Dusseldorf, Germany b State Key Laboratory for Corrosion and Protection, Institute of Metal Research, Chinese Academy of Science, Shenyang 110016, PR China |
| |
Abstract: | The technological process of Ce sealing of anodized LY12 (2024) alloy is introduced in this paper. The corrosion behavior of the film is studied by polarization curves and electrochemical impedance spectroscopy. The results show that the coating remains passive at the potential range from the open circuit potential (−780 mV) to −250 mV. After immersing the sample in NaCl solution for 6 days, the outer layer Ce conversion coating begins to loose its anticorrosive property. The inner Ce sealing anodized film is not corroded until 60 days immersion. Thus, the inner layer Ce sealing anodized film takes the leading role of the corrosion protection for LY12 alloy. |
| |
Keywords: | Aluminum alloy Anodic oxidation Cerium coating Corrosion |
本文献已被 ScienceDirect 等数据库收录! |
|