首页 | 本学科首页   官方微博 | 高级检索  
     


Suppression of saturation saliency effects for the sensorlessposition control of induction motor drives under loaded conditions
Authors:Teske  N Asher  GM Sumner  M Bradley  KJ
Affiliation:Sch. of Electr. & Electron. Eng., Nottingham Univ.;
Abstract:This paper presents an automated commissioning procedure used for the elimination of the saturation saliency effects in the sensorless position control of field-orientated cage induction motor drives. The position control itself is based on extracting a rotor position estimate from a high-frequency signal injection interacting with natural or engineered rotor position saliencies within the machine. The paper shows that this estimate cannot be robustly or accurately obtained if saturation saliencies are present. The paper introduces a method for suppressing the effects of the saturation saliency through information gained in a prior commissioning procedure. The effectiveness of the procedure is demonstrated through experimental results showing both good suppression of the saturation harmonics and true sensorless position control under high load torques
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号