首页 | 本学科首页   官方微博 | 高级检索  
     


Properties of the catalytic center of a secretory 28kDa protein (1-cys peroxiredoxin) from rat olfactory epithelium
Authors:VI Novoselov  IV Peshenko  VA Evdokimov  SS Kamzalov  SV Novoselov  IuV Nikolaev  MF Bystrova  EE Fesenko
Affiliation:H?pital Universitaire Saint-Jacques, Besan?on, France.
Abstract:BACKGROUND: Percutaneous mitral valvuloplasty with the Inoue balloon is conventionally performed with double vascular access: arterial and venous. However, in patients with a good echogenic window it may be performed with venous access only and the procedure monitored by 2D-echocardiography and colour flow mapping. This should result in early ambulation and hospital discharge with reduced arterial complications. AIMS: To compare retrospectively the immediate results of percutaneous mitral valvuloplasty with the Inoue balloon in two groups of patients: Group I: venous access only (no arterial access, n = 102) and Group II: conventional double vascular access (arterial and venous access, n = 275). METHODS AND RESULTS: The baseline characteristics of the two groups were comparable for age, sex, clinical, echocardiographic, radiological and haemodynamic variables. The mitral valve area (Group I: 1.1 +/- 0.3 to 1.85 +/- 0.5 cm2 vs Group II: 1.05 +/- 0.2 to 1.85 +/- 0.5 cm2, P = ns) and transmitral gradient (Group I: 11 +/- 4 to 4.7 +/- 2 mmHg vs Group II: 12 +/- 4 to 4.8 +/- 2 mmHg, P = ns) before and after mitral valvuloplasty were not statistically different. A good immediate result, defined as mitral valve area > 1.5 cm2 and mean mitral gradient < 5 mmHg with mitral regurgitation < or = 2+ at the end of the procedure, was observed in 77% of the cases in the venous-only group and 79% in the double access group (P = ns). The incidence of severe mitral regurgitation (Grade III or IV) was not statistically significant. Procedural duration (71 +/- 24 min vs 109 +/- 26 min, P < 0.01), fluoroscopic time (12.5 +/- 5.5 min vs 18.5 +/- 6 min, P < 0.01) and hospital stay (2.8 +/- 1.5 days vs 4.8 +/- 2.6 days, P < 0.001) were significantly shorter in the venous-only group than in the conventional Inoue series. CONCLUSION: Single venous access balloon mitral valvuloplasty is as equally safe and effective as double vascular access. The additional advantages of single venous access are shorter procedural duration, fluoroscopic time and hospital stay. We recommend that it be performed by an experienced operator (minimum of 100 trans-septal punctures) in patients without major thoracic deformity and a good echogenic window.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号