摘    要:针对某电厂500 MW机组塔式锅炉因受热面积灰污染而造成塌灰灭火、锅炉效率下降和局部受热面超温爆管等问题,建立了锅炉受热面污染状态监测系统,实现了对各级受热面实时污染状况的在线监测。在机组稳定负荷下,进行了受热面的吹灰试验。通过对试验结果的分析以及结合吹灰系统的运行状况,确定了锅炉各主要受热面的污染特性,据此提出了改造声波吹灰器、优化现有蒸汽吹灰器的运行方式等方案。实施后,吹灰系统运行状况良好,经济效益显著。

关 键 词:500MW机组  塔式锅炉  受热面  灰污染  吹灰系统  塌灰  

ANALYSIS OF HEATING SURFACE FOULING BEHAVIOR AND OPTIMIZED RETROFIT OF SOOT-BLOWING SYSTEM FOR TOWER TYPE BOILER OF 500 MW UNIT
YAN Weiping,DONG Jiancong,GAO Zhengyang,LIU Yimin,LI Wenlin,SU Huicong.ANALYSIS OF HEATING SURFACE FOULING BEHAVIOR AND OPTIMIZED RETROFIT OF SOOT-BLOWING SYSTEM FOR TOWER TYPE BOILER OF 500 MW UNIT[J].Thermal Power Generation,2011,40(8).
Authors:YAN Weiping  DONG Jiancong  GAO Zhengyang  LIU Yimin  LI Wenlin  SU Huicong
Affiliation:YAN Weiping1,DONG Jiancong1,GAO Zhengyang1,LIU Yimin2,LI Wenlin2,SU Huicong21.Key Laboratory for Condition Monitoring and control of Equipments in Power Plants under Ministry of Education,North China Electric Power University,Baoding 071003,Hebei Province,PRC2.Guowang Shentou Power Plant No.2,Shuozhou 036011,Shanxi Province,PRC
Abstract:Directing against the problems occured on a tower type boiler of 500 MW unit due to ash deposition and fouling on the heating surface,such as ash falling,fireout,reducing of boiler efficiency,local overtemperature and tube-burst on the heating surface etc.,a monitoring system of boiler's heating surface fouling has been established,realizing real-time on-line monitoring of the heating surface fouling situation.Under the stable load condition,a test of soot-blowing has been carried out on said heating surfac...
Keywords:500 MW unit  tower type boiler  heating surface  ash fouling  soot-blowing system  ash falling  