首页 | 本学科首页   官方微博 | 高级检索  
     

电感耦合等离子体质谱法测定高纯二氧化碲中10种杂质元素
引用本文:王长华,王伟华,韩维儒,侯亚丽,白伟华. 电感耦合等离子体质谱法测定高纯二氧化碲中10种杂质元素[J]. 冶金分析, 2021, 41(3): 39-43. DOI: 10.13228/j.boyuan.issn1000-7571.011192
作者姓名:王长华  王伟华  韩维儒  侯亚丽  白伟华
作者单位:1.国标(北京)检验认证有限公司,北京 101400; 2.北京环标科创环境科技发展有限责任公司,北京 100029
基金项目:工信部“2017年工业转型升级——国家新材料测试评价平台建设项目”(52801)
摘    要:杂质元素含量对保证高纯二氧化碲产品的纯度具有重要的意义.采用1.0 mL硝酸-5.0 mL盐酸-3.0 mL酒石酸溶液溶解样品,以133CS为内标元素,用动能歧视碰撞池(KED)模式测定钙、铁和硒,采用标准模式测定其他元素,建立了采用电感耦合等离子体质谱法(ICP-MS)测定高纯二氧化碲中镁、铝、钙、铁、镍、铜、硒、锑...

关 键 词:电感耦合等离子体质谱法(ICP-MS)  二氧化碲  杂质元素
收稿时间:2020-06-03

Determination of ten impurity elements in high purity tellurium dioxide by inductively coupled plasma mass spectrometry
WANG Changhua,WANG Weihua,HAN Weiru,HOU Yali,BAI Weihua. Determination of ten impurity elements in high purity tellurium dioxide by inductively coupled plasma mass spectrometry[J]. Metallurgical Analysis, 2021, 41(3): 39-43. DOI: 10.13228/j.boyuan.issn1000-7571.011192
Authors:WANG Changhua  WANG Weihua  HAN Weiru  HOU Yali  BAI Weihua
Affiliation:1. Guobiao (Beijing) Testing & Certification Co., Ltd., Beijing 101400, China; 2. Beijing Huanbiaokechuang Environmental Technology Development Co., Ltd., Beijing 100029, China
Abstract:The content of impurity elements was of great significance to guarantee the purity of high-purity tellurium dioxide products. The sample was dissolved with 1.0 mL of nitric acid-5.0 mL of hydrochloric acid-3.0 mL of tartaric acid solution. 133Cs was selected as the internal standard element. The contents of calcium, iron and selenium were determined by kinetic energy discrimination (KED) collision cell mode, and the contents of other elements were determined by the standard mode. A determination method of ten impurity elements including magnesium, aluminum, calcium, iron, nickel, copper, selenium, antimony, lead and bismuth in high-purity tellurium dioxide by inductively coupled plasma mass spectrometry (ICP-MS) was established. The limits of detection of this method were between 0.012 μg/L and 0.21 μg/L. The limits of quantification were between 0.040 μg/L and 0.59 μg/L. The high-purity tellurium dioxide samples were determined according to the experimental method. Each sample was determination for seven times in parallel. The relative standard deviations of determination results were between 1.2% and 3.4%. The recoveries were between 95% and 106%. The proposed method was applicable for the determination of tellurium dioxide materials with purity of 99.999%.
Keywords:inductively coupled plasma mass spectrometry (ICP-MS)  tellurium dioxide  impurity elements  
本文献已被 CNKI 等数据库收录!
点击此处可从《冶金分析》浏览原始摘要信息
点击此处可从《冶金分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏