山铝热电厂01#循环流化床锅炉膜式省煤器改造
引用本文:陆志军,王晶.山铝热电厂01#循环流化床锅炉膜式省煤器改造[J].锅炉制造,2006(3):31-32.
作者姓名:陆志军  王晶
作者单位:1. 山东铝业股份有限公司热电厂,山东,淄博,255052
2. 中铝山东分公司设计院,山东,淄博,255052
摘    要:山东铝业股份有限公司热电厂01#循环流化床锅炉省煤器自投产以来频繁出现爆管故障,通过对历次故障情况进行综合分析,提出了减少省煤器管排数、改善防磨结构、降低烟气流速减轻磨损的膜式省煤器改造方案,改造实施后运行效果良好。

关 键 词:流化床锅炉  磨损  膜式省煤器  改造
文章编号:CN23-1249(2006)03-0031-02
收稿时间:2006-04-13
修稿时间:2006年4月13日

Renovation of Membrane Economizer of CFB in Shandong Aluminum Company Heat and Power Plant 01#
Lu Zhijun,Wang Jing.Renovation of Membrane Economizer of CFB in Shandong Aluminum Company Heat and Power Plant 01#[J].Boiler Manufacturing,2006(3):31-32.
Authors:Lu Zhijun  Wang Jing
Abstract:Tube Rupture happened frequently since CFB in Shandong Aluminum Company Heat and Power Plant 01 # put into product, through analysis of accident condition,renovation measures were taken, such as reducing economizer tube number, improving anti - wear structure, slowing flue gas rate to improve operation status.
Keywords:CFB  wear  membrane economizer  renovation