王瑶水库泄洪洞破坏原因及加固措施 |
| |
引用本文: | 方卫红.王瑶水库泄洪洞破坏原因及加固措施[J].电网与水力发电进展,2001,17(2):17-18. |
| |
作者姓名: | 方卫红 |
| |
作者单位: | 方卫红(水利部陕西水利电力勘测设计研究院,陕西西安 710001) |
| |
摘 要: | 介绍了王瑶水库泄洪洞明流段底板及侧墙的破坏现状及所造成的原因分析,提出采用钢筋网加钢纤维混凝土喷锚处理措施来修补被破坏的结构是一种有效、方便的工程措施.为钢纤维混凝土在水工结构上的应用提供一些可借鉴的经验.
|
关 键 词: | 泄洪洞 原因分析 钢纤维混凝土 处理措施 |
文章编号: | 1002-1876(2001)02-0017-02 |
修稿时间: | 2001年2月28日 |
The damage causation in the discharge tunnel and consolidation easures of Wangyao Reservoir |
| |
Authors: | FANG Wei-hong |
| |
Abstract: | The actuality and damage causation of base plate in free surface flow section and side wall of the discharge tunnel are analyzed. B ased on the analysis, the mesh reinforcement with steel fibre are used to anchor the damaged parts in practice, which is a efficient and simple measure for repa iring the damaged section of water works. The method may provide some reference for other project. |
| |
Keywords: | discharge tunnel damage causation analysis steel fibre reinforced concrete consolidation measures |