首页 | 本学科首页   官方微博 | 高级检索  
     

法兰氦质谱检漏技术
引用本文:胡茂中,廖旭东,冯晓,陈涛.法兰氦质谱检漏技术[J].无损检测,2007,29(5):272-274.
作者姓名:胡茂中  廖旭东  冯晓  陈涛
作者单位:西北核技术研究所,西安,710024
摘    要:改进并设计加工了法兰检漏专用吸枪和喷枪。研究和提出了充压真空法与氦罩法对法兰整体检漏的方法,利用法兰多道密封结构形成的环状空腔作为检漏真空室,进一步提高了法兰检漏的灵敏度与可靠性。

关 键 词:充压真空法  氦罩法  整体检漏
文章编号:1000-6656(2007)05-0272-03
收稿时间:2006-09-28
修稿时间:2006年9月28日

Helium Mass Spectrometer Leak Testing for the Flange
HU Mao-zhong,LIAO Xu-dong,FENG Xiao,CHEN Tao.Helium Mass Spectrometer Leak Testing for the Flange[J].Nondestructive Testing,2007,29(5):272-274.
Authors:HU Mao-zhong  LIAO Xu-dong  FENG Xiao  CHEN Tao
Affiliation:The North-West Institute of Nuclear Technology, Xian 710024, China
Abstract:The special sniffing probe and spray probe for leak testing of flange were designed and made.The inside-out testing and hood testing,two overall leak detection methods,were made research on and established.In these methods,the cavity which was ringed by multi-layer tight structures in the flange was used as the vacuum cave in leak detecting.By these means,the sensitivity and reliability of the leak detection for the flange were further improved.
Keywords:Inside-out testing method  Hood testing method  Overall leak detection method
本文献已被 CNKI 维普 万方数据 等数据库收录!