大容量燃煤电站锅炉回转式空气预热器漏风分析及控制措施
引用本文:王冬. 大容量燃煤电站锅炉回转式空气预热器漏风分析及控制措施[J]. 河北电力技术, 2006, 25(4): 29-32
作者姓名:王冬
作者单位:华北电力大学动力工程系,北京,102206
摘    要:分析600 MW等级大容量燃煤电站锅炉回转式空气预热器漏风产生的原因和控制措施,并对当前工程实际中空气预热器的性能评价方法和指标进行了论证,提出了较为科学的观点。

关 键 词:回转式空气预热器  漏风  控制措施
文章编号:1001-9898(2006)04-0029-04
收稿时间:2006-04-17
修稿时间:2006-04-17

Analysis on Rotary Air Preheater Air Leakage of Large Coal-fired Power Plant Boiler and Control Measures
WANG Dong. Analysis on Rotary Air Preheater Air Leakage of Large Coal-fired Power Plant Boiler and Control Measures[J]. Hebei Electric Power, 2006, 25(4): 29-32
Authors:WANG Dong
Abstract:Causes and control measures of rotary air preheater air leakage of 600 MW coal - fired power plant boiler are analyzed, after that, according to the demonstration of performance evaluation methods and the target of air preheater in the construction, scientific opinions are raised.
Keywords:rotary air preheater   air leakage   control measure