首页 | 本学科首页   官方微博 | 高级检索  
     

水平安装文丘里管在低压湿气流动下的特性
引用本文:方立德,张涛.水平安装文丘里管在低压湿气流动下的特性[J].中国化学工程学报,2008,16(2):320-324.
作者姓名:方立德  张涛
作者单位:Key Laboratory for Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China
基金项目:国家高技术研究发展计划(863计划)
摘    要:The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.

关 键 词:gas-liquid  two  phase  flow  wet  gas  metering  Venturi  meter  over-reading  
收稿时间:8 May 2007
修稿时间:2007年5月8日

Performance of a horizontally mounted Venturi in low-pressure wet gas flow
FANG Lide,ZHANG Tao.Performance of a horizontally mounted Venturi in low-pressure wet gas flow[J].Chinese Journal of Chemical Engineering,2008,16(2):320-324.
Authors:FANG Lide  ZHANG Tao
Affiliation:Key Laboratory for Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China
Abstract:The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is dis-cussed. Three 50 mm Venturi meters were tested systematically, with β values of 0.4048, 0.55 and 0.70, the opera-tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99.The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio,and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore,low-pressure performance was compared with that under high pressure.
Keywords:gas-liquid two phase flow  wet gas metering  Venturi meter  over-reading
本文献已被 维普 万方数据 ScienceDirect 等数据库收录!
点击此处可从《中国化学工程学报》浏览原始摘要信息
点击此处可从《中国化学工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号