摘    要:对某机场地源热泵系统地埋管换热器的换热性能进行了测试,计算得出了热泵机组和系统的能效比,进而评价了整个空调工程在运行阶段的能效水平.重点介绍了测试台的搭建、低温测试的主要参数.

关 键 词:地埋管换热器  地源热泵系统  能效比  数据分析

Ground-source heat pump system design and operating energy efficiency analysis of an air force airport
Luo Jijie,Zhang Qiang. Ground-source heat pump system design and operating energy efficiency analysis of an air force airport[J]. Journal Heating Ventilating and Airconditioning, 2009, 39(7)
Authors:Luo Jijie  Zhang Qiang
Abstract:Tests the performance of ground heat exchangers of the system. Calculates the energy efficiency ratio of the heat pump and the system. Evaluates the energy efficiency of the whole air conditioning project in operating stage. Emphatically presents the establishment of the testing table and the main parameters of the low temperature test.
Keywords:ground heat exchanger  ground-source heat pump system  energy efficiency ratio  data analysis  