首页 | 本学科首页   官方微博 | 高级检索  
     


Solid Food Thermal Conductivity Determination at High Temperatures
Authors:J. P. GRATZEK  R. T. TOLEDO
Affiliation:Authors Gratzek and Toledo are with the Dept. of Food Science &Technology, the Univ. of Georgia, Athens, GA 30602.
Abstract:Thermal conductivity of carrots and potatoes was measured using a line heat source probe adapted for measurements to 130°C. Fastest response and rapid attainment of linearity in temperature rise vs In time plots, were obtained with a silicone oil-filled probe with an uninsulated thermocouple junction. Custom designed electronics to amplify thermocouple output, and computer control of measurements, data acquisition and analysis resulted in 0.4% data repeatability (two standard deviations) for calibration standards. Thermal conductivity of carrot and potato vs temperature agreed well with the published volume fraction model for multi-component foods.
Keywords:thermal conductivity    carrots    potatoes    rapid determination
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号