高强钢厚壁管失效评定图技术研究 |
| |
引用本文: | 邓阳春,柳曾典.高强钢厚壁管失效评定图技术研究[J].化工机械,1998,25(2):86-87,37. |
| |
作者姓名: | 邓阳春 柳曾典 |
| |
作者单位: | [1]湖北省锅炉压力容器检验研究所 [2]华东理工大学 |
| |
摘 要: | 按英国CEGBR6第3版选择2的方法制定高强钢厚壁管失效评定图(FAD)。根据测试材料断裂韧性试样的有限元计算和实验所获得的选择3FAD初步验证选择2FAD的有效性。
|
关 键 词: | 高强钢 厚壁管 失效评定图 有效性 |
Research of the failure assessment diagram technology of thick-walled high strength steel tubings |
| |
Abstract: | The failure assessment diagram of the thick walled high strength steel tubings was drawn based on the Option 2 Method,the 3rd edition,CEBE.The Option 2 FAD was considered efficient through the finite element analysis of the samples of fracture toughness of the tested materials and the Option 3 derived from experiments. |
| |
Keywords: | High Strength Steel Thick-Walled Tubing Failure Assessment Diagram Efficiency |
本文献已被 CNKI 维普 等数据库收录! |