Pressure Drop Control Using Multiple Orifice System in Compressible Pipe Flows
作者姓名:HeuydongKim  ToshiakiSetoguchi
作者单位:Heuydong Kim School of Mechanical Engineering,Andong National University,388,Songchun-dong,Andong 760-749,Korea Toshiaki Setoguchi Shigeru Matsuo Department of Mechanical Engineering,Saga University,1,Honjo-Machi,Saga 840-8502,Japan S. R. Raghun
摘    要:hauctionFlow Wgh deviCes SUch as an ondce, noZile,Venha, chser and bend has been Of grea interest tOdesiM of flow systeInS. These devices are ofte usedto change Pressure, velocity or direeon of fiuld flowand thN could be regarded as flow contrl devices.The ondce is a flow control device of PraCticaltwOrtane as it is simPIe to design and manUhaur andis also cost Whve. The orifice is bette undetheod asan inM for measUreInen Of flow rates in a fiowsyam.There have been systeInatic inVes…

关 键 词:喷嘴  压强控制  可压缩流体

Pressure drop control using multiple orifice system in compressible pipe flows
Heuydong Kim,Toshiaki Setoguchi,Shigeru Matsuo,S. R. Raghunathan.Pressure Drop Control Using Multiple Orifice System in Compressible Pipe Flows[J].Journal of Thermal Science,2001,10(4):309-317.
Authors:Heuydong Kim  Toshiaki Setoguchi  Shigeru Matsuo  S R Raghunathan
Affiliation:(1) School of Mechanical Engineering, Andong National University, 388, Songchun-dong, 760-749 Andong, Korea;(2) Department of Mechanical Engineering, Saga University, 1, Honjo-Machi, 840-8502 Saga, Japan;(3) Department of Aeronautical Engineering, The Queen’s University of Belfast, David Keir Building, Stranmillis Road, BT7 5AG Belfast, Northern Ireland, UK
Abstract:In order to investigate the effectiveness of an orifice system in producing pressure drops and the effect of compressibility on the pressure drop, computations using the mass-averaged implicit Navier-Stokes equations were applied to the axisymmetric pipe flows with the operating pressure ratio from 1.5 to 20.0. The standard k- ɛ turbulence model was employed to close the governing equations. Numerical calculations were carried out for some combinations of the multiple orifice configurations. The present CFD data showed that the orifice systems, which have been applied to incompressible flow regime to date, could not be used for the high operating pressure ratio flows. The orifice interval did not strongly affect the total pressure drop, but the orifice area ratio more than 2.5 led to relatively high pressure drops. The total pressure drop rapidly increased in the range of the operating pressure ratio from 1.5 to 4.0, but it nearly did not increase when the operating pressure ratio was over 4.0. In the compressible pipe flows through double and triple orifice systems, the total pressure drop was largely due to shock losses.
Keywords:compressible flow  internal flow  shock wave  multiple orifice  flow control  