新投运变压器油中氢气异常的分析与处理
引用本文:刘娟. 新投运变压器油中氢气异常的分析与处理[J]. 高压电器, 2007, 43(4): 318-320
作者姓名:刘娟
作者单位:衢州电力局,浙江,衢州,324002
摘    要:通过几台新投运变压器运行后产生高浓度氢气现象的案例,结合实际,分析了氢产生的原因,并提供了不同的处理方法,对其他设备发生同类现象的原因分析和判断、处理提供借鉴。

关 键 词:新投运变压器  氢气  色谱跟踪  处理
文章编号:1001-1609(2007)04-0318-03
修稿时间:2007-05-082007-07-12

Analysis and Solutions of Oil H2 Gas Abnormity of the New Transformer in Service
LIU Juan. Analysis and Solutions of Oil H2 Gas Abnormity of the New Transformer in Service[J]. High Voltage Apparatus, 2007, 43(4): 318-320
Authors:LIU Juan
Affiliation:Quzhou Electric Power Bureau, Quzhou 324002, China
Abstract:Combined with the cases of the high H2 content occurred in several new transformers,the reasons of this phenomenon were analyzed,and different solutions were also provided,which would be helpful to analyze and treat with the similar faults in other equipments.
Keywords:new running transformer  hydrogen gas  chromatogram track  treatment