摘    要:近年来在水泥厂带补燃的余热电站设计中普遍地采用了循环流化床锅炉做为补燃锅炉。CPC循环流化床锅炉是其中应用较多的一种。针对这种锅炉在某水泥厂余热电站的实际运行中出现的结渣现象。文章分析了其结渣的原因及解决办法;对余热电站的设计及循环流化床锅炉的运行有参考意义。

关 键 词:余热电站  锅炉  循环流化床  结焦
文章编号:1004-8774(2001)02-0036-04
修稿时间:2000年12月11

Analysis of the FI CIRCTM Fluidized Bed Boiler Slagging in Waste Heat Power Station in Cement Plant
Zhang Fu-bin.Analysis of the FI CIRCTM Fluidized Bed Boiler Slagging in Waste Heat Power Station in Cement Plant[J].Industrial Boiler,2001(2):36-39.
Authors:Zhang Fu-bin
Abstract:Recently, the circular fluidized bed supplementary boiler was universally used by designing the waste heat power station in cement plant, one of which preferably used is CPC circular fluidized bed boiler. This paper analyses the causes and resolvents of slagging in the waste heat power station. This will be reference to design the waste heat power station and operate the circular fluidizeb bed boiler.