摘    要:针对电力变压器有载分接开关运行中出现的渗油故障,分析、判断、验证产生故障的原因和处理方法,提出具体的预防措施。经实践证明,该方法大大降低了有载分接开关渗油故障率,确保主变安全稳定运行。

关 键 词:有载分接开关  渗漏  判断  分析处理

Judgment and Treatment on Main Transformer On-load Tap-changer Oil Leakage
LIU Yong , ZHAO Yi.Judgment and Treatment on Main Transformer On-load Tap-changer Oil Leakage[J].Shanxi Electric Power,2012(3):45-46.
Authors:LIU Yong  ZHAO Yi
Affiliation:(Linfen Power Supply Company,Linfen,Shanxi 041000,China)
Abstract:Oil leakage occurred in on-load tap-changer of transformer.In order to solve the problem,the fault was analyzed,judged and verified with measures being proposed to prevent its occurrence.Proved by practice,this method greatly reduces the on-load tap-changer oil leakage and ensures the stable operation of main transformer.
Keywords:on-load tap-changer  leakage  judgment  analysis and process