首页 | 本学科首页   官方微博 | 高级检索  
     


Arsenic removal from Bangladesh tube well water with filter columns containing zerovalent iron filings and sand
Authors:Leupin Olivier X  Hug Stephan J  Badruzzaman A B M
Affiliation:Swiss Federal Institute of Aquatic Science and Technology (Eawag), Uberlandstrasse 133, CH-8600 Dübendorf Switzerland.
Abstract:Arsenic removal is often challenging due to high As(III), phosphate, and silicate concentrations and low natural iron concentrations. Application of zerovalent iron is promising, as metallic iron is widely available. However, removal mechanisms remained unclear and currently used removal units with iron have not been tested systematically, partly due to their large size and long operation time. This study investigated smaller filter columns with 3-4 filters, each containing 2.5 g of iron filings and 100-150 g of sand. At a flow rate of 1 L/h, these columns were able to treat 75-90 L of well water with 440 microg/L As, 1.8 mg/L P, 4.7 mg/L Fe, 19 mg/L Si, and 6 mg/L dissolved organic carbon (DOC) to below 50 microg/L As(tot), without addition of an oxidant. As(III) was oxidized in parallel to oxidation of corrosion-released Fe(II) by dissolved oxygen and sorbed on the forming hydrous ferric oxides (HFO). The open filter columns prevented anoxic conditions. DOC did not appear to interfere with arsenic removal. Manganese was reduced after a slight initial increase from 0.3 mg/L to below 0.1 mg/L. About 100 mg of Fe(0)/L of water was required, 3-5 times less than that for larger units with sand and iron turnings.
Keywords:
本文献已被 PubMed 等数据库收录!