Abstract:OBJECTIVE: We examined the test-retest reliability and the construct validity of the measurement of knee position sense for describing the functional weightbearing performance of women with osteoarthritis (OA) of the knee. METHODS: For the purpose of this study, position sense was defined as the error occurring when subjects attempted to reproduce a criterion angle in standing with visual cues eliminated. Five such tests were recorded photographically on 3 different occasions. On each occasion the 10 subjects also completed a self-paced walking test over a 13 m indoor walkway. RESULTS: The photographic measurements were reproducible (r = 0.90) and there was no change in positioning accuracy across sessions. There was a significant (p < 0.05) inverse correlation of 0.70 between the standard deviation of the mean individual measurements of position sense (precision of the test) and those of walking speed. CONCLUSION: Our study demonstrates good measurement reliability and a comparable mean angular error with repeated tests. It also suggests the amplitude of the variability of this error is a strong determinant of an individual OA patient's functional performance in walking.