首页 | 本学科首页   官方微博 | 高级检索  
     


Operation and control of coupled nonequilibrium disk MHD generator and inverter system under power line fault condition
Authors:Yoshitaka Inui  Motoo Ishikawa  Hiroshi Hayashida
Abstract:Numerical simulations of detailed time‐dependent behavior are performed on a simulation model in which a coupled system of nonequilibrium disk MHD generator and line‐commutated inverter is connected to an infinite bus through the transmission line, showing that continuous operation of the system is usually possible even when a power line fault occurs near the system. Then, time‐dependent swing simulations are carried out on another simulation model in which the MHD/inverter system and a synchronous generator are connected in parallel to an infinite bus through the common transmission line, revealing that the rotor angle swing of the synchronous generator caused by the power line fault can be effectively suppressed by the fast output power control of the MHD/inverter system. © 1999 Scripta Technica, Electr Eng Jpn, 127(3): 13–24, 1999
Keywords:nonequilibrium MHD power generation  disk generator  line‐commutated inverter  synchronous generator  swing suppression control
设为首页 | 免责声明 | 关于勤云 | 加入收藏