首页 | 本学科首页   官方微博 | 高级检索  
     

超声波液体密度测量的一种声反射系数测定方法
引用本文:李晓佳,刘佳鑫,李国锋.超声波液体密度测量的一种声反射系数测定方法[J].传感技术学报,2017,30(7).
作者姓名:李晓佳  刘佳鑫  李国锋
作者单位:1. 大连理工大学电气工程学院,辽宁 大连,116024;2. 国网辽宁省电力有限公司电力科学研究院,沈阳,110006
摘    要:用超声波测液体密度时,测量声反射系数是重点.提出一种将半波层反射模型简化后,利用相对稳态幅度测量声压反射系数的方法.将一个较薄固体作为半波层置于被测液体中,两侧对称地放置超声波换能器,换能器一个工作在脉冲回波模式,另一个工作在接收模式.调整信号频率使半波层和被测液体交界面的多重反射波达到最大程度干涉,此时被测液体与半波层之间的声反射系数只与两个换能器在稳态下的回波信号幅度比值有关.因此测得换能器的稳态回波信号幅度比,即可得到声反射系数.此方法简化了原来的半波层反射模型,采取对称布局,利用相对稳态幅度法,简化了理论推导过程,降低了测量上的精度要求.最后文章通过实验验证了方法的正确性.

关 键 词:超声传感器  声反射系数  半波层反射法  简化模型  相对稳态幅度法  液体密度测量

A method for measuring the acoustic reflection coefficient of liquid density measurement by ultrasonic wave
LI Xiaojia,LIU Jiaxin,LI Guofeng.A method for measuring the acoustic reflection coefficient of liquid density measurement by ultrasonic wave[J].Journal of Transduction Technology,2017,30(7).
Authors:LI Xiaojia  LIU Jiaxin  LI Guofeng
Abstract:Measurement of acoustic reflection coefficient is the key point when measuring the density of liquid by ultrasonic wave.This paper presents a method for measuring the acoustic reflection coefficient through the relative steady state amplitude based on the simplified model of half wave reflection.A thin solid as a half wave layer is arranged in the measured liquid,and two ultrasonic transducers are placed on both sides of the measured liquid,symmetrically.One transmitter works in pulse-echo mode,and the other works in receiver mode.By adjusting the frequency of signal to make the multiple reflection wave at the interface between the half wave layer and the liquid interfere to the greatest extent,the acoustic reflection coefficient between the liquid and the half wave layer is only related to the amplitude ratio of the two transducers in steady state.So the sound acoustic reflection coefficient can be obtained when the echo signal amplitude ratio of the transducer in steady state is measured.This method simplifies the process of theoretical derivation and reduces the accuracy of the measurement,by simplifying the original half wave reflection model,taking the symmetrical layout and using the method of relative steady state amplitude.At last,experiments are carried out to verify this method.
Keywords:ultrasonic sensor  acoustic reflection coefficient  half wave reflection method  relative steady state amplitude method  liquid density measurement
本文献已被 万方数据 等数据库收录!
点击此处可从《传感技术学报》浏览原始摘要信息
点击此处可从《传感技术学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号