摘    要:研究了低压电器大电流试验装置的校准。针对新的计量校准方法,阐述了延时试验装置、瞬时试验装置和通断试验装置的校准原理和方法,列出了注意事项。该校准方法缩短了设备计量时间,提高了试验设备的使用效率。

关 键 词:计量  校准  大电流试验装置

Research of Calibration of Heavy Current Tester for Low Voltage Electrical Apparatus
MA Jiuxu,JIANG Deyuan.Research of Calibration of Heavy Current Tester for Low Voltage Electrical Apparatus[J].Low Voltage Apparatus,2007(17):43-44.
Authors:MA Jiuxu  JIANG Deyuan
Abstract:The calibration of heavy current tester for low voltage electrical apparatus was studyed.Aiming at new measurement calibration method,the calibration principle and method of delay tester,instantaneousness tester and make-break tester were expounded,and attention items were also listed.The calibration method shortens the measurement time of equipment calibration and improves application efficiency of tester.