精氩塔不凝气排放止回阀故障的影响及处理
引用本文:赵高峰,陈治国.精氩塔不凝气排放止回阀故障的影响及处理[J].深冷技术,2006(3):58-59.
作者姓名:赵高峰  陈治国
作者单位:河南豫光金铅股份有限公司制氧厂,河南省济源市济水大街中段525号454650
摘    要:详细介绍了6000m3/h空分设备精氩塔不凝气排放止回阀故障而导致精氩塔发生氮塞,进而影响整个制氩系统运行工况不稳定的现象,提出了解决的方法,采取相应措施后,排除了故障。

关 键 词:大型空分设备  制氩系统  精氩塔  氮塞  止回阀
文章编号:1009-9425(2006)03-0058-02
收稿时间:2005-06-01
修稿时间:2005年6月1日

Effect and treatment of a fault with the noncondensing gas exhausting check valve in pure argon column
Zhao Gao-feng, Chen Zhi-guo.Effect and treatment of a fault with the noncondensing gas exhausting check valve in pure argon column[J].Cryogenic Technology,2006(3):58-59.
Authors:Zhao Gao-feng  Chen Zhi-guo
Abstract:An unstable operation of argon-producing system in a 6000m^3/h air separation unit has been described in details, which was caused by nitrogen block in pure argon column due to a fault with the noncondensing gas exhausting check valve. Corresponding solutions have been proposed and carried out to clear the fault.
Keywords:Large scale air separation unit  Argon- producing system  Rectification column  Nitrogen block  Check valve