首页 | 本学科首页   官方微博 | 高级检索  
     


Applicability of alkaline hydrolysis for remediation of TNT-contaminated water
Authors:Hwang Sangchul  Ruff Timothy J  Bouwer Edward J  Larson Steven L  Davis Jeffrey L
Affiliation:Department of Civil Engineering and Surveying, University of Puerto Rico at Mayagüez, PR 00680, USA. shwang@uprm.edu
Abstract:This study was conducted to assess the applicability of alkaline hydrolysis as an alternative ex situ technology for remediating 2,4,6-trinitrotoluene (TNT)-contaminated water. TNT reactivity had a strong dependence on the reaction pH (11-12) and initial TNT (5-25 mg L(-1)) in batch systems, resulting in pseudo first-order transformation rate, k ranging between 1.9 x 10(-3) and 9.3 x 10(-5) min(-1). In continuous flow stirred-tank reactor (CFSTR) systems with initial TNT of 1 mg L(-1), the highest 74% of TNT reduction was achieved at the reaction pH of 11.9 and 2-day hydraulic retention time under steady-state condition. Oxalate was produced as the major hydrolysate in the CFSTRs, indicating a ring cleavage during alkaline hydrolysis. It was also believed that TNT alkaline hydrolysis occurred through the production of color-forming intermediates via dimerization. It is concluded that alkaline hydrolysis can be an alternative treatment technology for remediation of TNT-contaminated water.
Keywords:Alkaline hydrolysis  Batch reactor  Continuous flow stirred-tank reactor  2  4  6-trinitrotoluene